OUR METHOD
Verifiable commitments in every intervention
What is delivered can be checked. These are the four commitments that come with every job.
01
A written report for each intervention, with the scope, the date and the personnel involved.
02
Camera verification at the same points, before and after cleaning.
03
An explicit record of the sections that could not be cleaned, with the reason.
04
The report belongs to the client and can be used with any provider.
The eight phases, with the equipment used and what is documented in each one, are explained on the service page.
Each decision in the method rests on a public reference. The table shows the match and links to the source of every point.
| Method practice | What the evidence says | Source |
|---|---|---|
| Filtered vacuum extraction during cleaning | In a study of eight homes, particles and bioaerosols were higher while cleaning was under way than before or after. The EPA warns that an inadequate vacuum collection system can release more dust than leaving the ducts as they are. | Ahmad et al., 2001 and EPA |
| Air handling unit, coil, pan and drain within the scope | The EPA lists the condensate pans of air handling units among the places with possible hidden mold. In a system that looked clean, 10⁵ to 10⁶ viable bacteria per cm² were counted on the coil fins. | EPA, chapter 3 and Hugenholtz and Fuerst, 1992 |
| Correcting the source of moisture | If the cause of the moisture is not corrected, mold returns. | EPA |
| Disinfection with a product suitable for ducts | Some products are registered as sanitizers for hard surfaces, such as sheet metal. The EPA states that no chemical biocides are registered for internally insulated ducts and that little research exists on their effectiveness inside ducts. That is why the report records the product applied and the sectors treated. | EPA |
| Findings on internal insulation | When fiberglass duct liner is contaminated with mold, cleaning is not enough to prevent regrowth. The EPA states it should be removed and replaced. The report records the finding with that recommendation. | EPA |
| Camera verification at the same points | NADCA’s ACR standard, in its 2025 edition, describes cleaning verification through the surface comparison test and the vacuum test. The method adds photographs and video of the before and after at the same points. | NADCA, ACR 2025 |
Limits. The EPA states that duct cleaning has never been shown to prevent health problems and does not recommend it as a routine. A literature review (Zuraimi, Indoor Air, 2010) concluded that the evidence is insufficient to claim benefits for air quality, health, savings or system performance. That is why this method does not promise health or consumption results: it describes the state of the system, what is done and what is checked.
Each advantage corresponds to one of the four commitments of the method and can be checked in the delivered document. The method offers no results about the people who occupy the building.
| What is gained | What it involves | Reference |
|---|---|---|
| Traceability of who did what | The report carries the scope, the date and the staff involved, and that identification makes it possible to reconstruct the work long afterwards, even if the administrative team has changed. | First commitment: a written report for each intervention. |
| Pairs of images and not only a story | By repeating the same points before and after, every verification photo has its earlier partner. The review is visual and any third party can do it. | Second commitment: camera verification at the same points. |
| The limit of the work, in plain view | Sections that could not be cleaned appear with their reason, and a partial cleaning is not presented as complete. It is thus clear what was delivered and what remains pending. | Third commitment: a record of what could not be cleaned. |
| Freedom to choose a provider | The report is the client’s property and can be shown to an insurer or to whoever quotes the same job. Nothing requires staying with Climatiza for the document to be useful. | Fourth commitment: the report belongs to the client. |
The three references support method decisions and not results. They are cited with their scope and are not presented as Climatiza seals.
| Data point | Source | Scope |
|---|---|---|
| The 2025 edition of the NADCA ACR standard organizes the work into assessing, cleaning, restoring and verifying, and provides two verification tests: surface comparison and vacuum. The method adds photos and video at the same points. | NADCA, ACR standard, 2025 | Reference method of the sector, not a Climatiza seal. |
| The EPA guide recognizes four reasons to clean ducts: abundant visible mold, vermin, ducts clogged with dust and debris, and particles coming out of the registers. Outside those cases, the method proposes documenting and inspecting again. | EPA, cleaning air ducts at home | Residential guide. It sets no frequencies for commercial buildings. |
| For schools and commercial buildings, the EPA places condensate pans among the places with possible hidden mold and asks that they be clean, flowing and free of obstructions. Hence the report describes the drain as well as the duct. | EPA, chapter 3 and chapter 2 of the same guide | United States guide for schools and commercial buildings. |
Any reader of the report can repeat these checks without being technical. They help establish whether the document matches what the method says it delivers.